Commercial plumbing emergency? Call now · Austin, Round Rock, Cedar Park & Central TexasCall (512) 555-0147

Grease Trap Size Calculator (Austin Water Method)

Add each fixture that drains to the grease interceptor. The calculator applies Austin Water's sizing method: total fixture units × 3 gallons per minute gives the flow rating, and the flow rating × 12 minutes gives the minimum liquid capacity. Austin Water won't approve anything under 100 gallons, and a kitchen with a dishwasher needs at least 500 gallons.

Fixtures that drain to the interceptor

One row per fixture type. Use the trap or arm size from the plumbing plan. If you're not sure, pick the larger size.

Minimum interceptor size

0 gallons

Total fixture units
0
Flow rating (FU × 3 gpm)
0
Capacity (flow × 12 min)
0
Austin Water minimum
100 gal
How this was counted
    Get a licensed plumber to size and install it

    Get Austin Water's Industrial Waste approval letter before you buy an interceptor. This is an estimate, not the approval.

    Austin Water fixture unit values

    Fixture units by trap or arm size, as published in Austin Water's grease trap sizing criteria.

    Fixture units by fixture and trap size
    FixtureConnectionFixture units
    3-compartment sinkThrough a floor sink or hub drain4 (2") / 6 (3") / 8 (4")
    2-compartment sinkThrough a floor sink or hub drain4 (2") / 6 (3") / 8 (4")
    1-compartment sinkThrough a floor sink or hub drain4 (2") / 6 (3") / 8 (4")
    DishwasherThrough a floor sink or hub drain6 (3") / 8 (4")
    Wok stoveThrough a floor sink or hub drain4 (2") / 6 (3") / 8 (4")
    Hand sink (through a floor sink)Through a floor sink or hub drain2 (2") / 3 (3") / 4 (4")
    Mop sink (through a floor sink)Through a floor sink or hub drain2 (2") / 3 (3") / 4 (4")
    Floor sink, cold clear water onlyThrough a floor sink or hub drain2 (2") / 3 (3") / 4 (4")
    Hub drain, cold clear water onlyThrough a floor sink or hub drain0 (2") / 0 (3") / 0 (4")
    Hand sink (connected directly)Direct0 (2") / 0 (3")
    Mop sink (connected directly)Direct2 (2") / 3 (3") / 4 (4")
    Floor drainDirect2 (2") / 3 (3") / 4 (4")
    Floor sink, no food equipment aboveDirect3 (3") / 4 (4")
    Trench drain, condensate onlyDirect2 (2") / 3 (3") / 4 (4")
    Trench drain, grease-bearingDirect4 (2") / 6 (3") / 8 (4")
    Garbage disposal or grinderThrough a floor sink or hub drainProhibited

    Source: Austin Water, Grease Trap Sizing Design Criteria.

    The rules the calculator uses

    Flow rating
    Total fixture units × 3 gallons per minute.
    Minimum liquid capacity
    Flow rating × 12 minutes of retention (7 minutes in the first compartment, 5 in the second).
    Smallest approved size
    100 gallons. Anything smaller is not approved for installation.
    Kitchens with a dishwasher
    At least a 500-gallon grease interceptor.
    Garbage disposals and grinders
    Prohibited in commercial kitchens in Austin.

    How to use the grease trap size calculator

    List every fixture that drains to the interceptor. Use the kitchen plumbing plan or walk the kitchen with your contractor. Add a row for each fixture type and set how many there are.

    Pick the trap or arm size. Fixture units depend on the drain size: a 3-compartment sink on a 2-inch trap counts 4, on a 3-inch trap 6, and on a 4-inch trap 8. If you don't know the size, use the larger one for a conservative estimate.

    Read the result as a minimum. The calculator shows the fixture units, the flow rating and the minimum gallons, then applies Austin Water's 100-gallon and 500-gallon minimums. Round up to the next standard interceptor size.

    Before you buy an interceptor

    Austin Water advises getting building plan approval and an Industrial Waste approval letter that states the required size and design before you purchase a grease trap or interceptor. An interceptor bought before approval can be rejected and has to be replaced. Use this calculator to budget and to check a design, not as the approval.

    Interceptor size also drives your pumping bill. In the City of Austin a trap must be pumped at least every three months, or sooner when grease and solids reach 50% of the wetted height (Austin City Code §15-10-197). A trap that's too small for the kitchen fills faster and gets pumped more often. See grease trap cleaning and pumping, the compliance calendar, restaurant plumbing, and for the lines that feed the trap, hydro jetting costs.

    Outside the City of Austin

    Round Rock, Cedar Park, Georgetown, Pflugerville, San Marcos and other nearby cities run their own pretreatment programs and may size interceptors differently. The calculator follows Austin Water's method. Check with your city's utility before you finalize a design, or request a quote and a licensed plumber who works in your city can size it.

    Frequently asked questions

    How do you size a grease trap in Austin?

    Austin Water adds up the fixture units of everything that drains to the trap, multiplies by 3 gallons per minute to get the flow rating, then multiplies by 12 minutes to get the minimum liquid capacity in gallons. The result can't be under 100 gallons, and kitchens with a dishwasher need at least 500 gallons.

    What size grease trap does a small restaurant need?

    It depends on the fixtures. A kitchen with one 3-compartment sink on a 3-inch trap, a mop sink and two floor drains on 2-inch traps works out to 6 + 2 + 4 = 12 fixture units, a 36 gpm flow rating and a 432-gallon minimum. Add a dishwasher and the minimum becomes at least 500 gallons.

    Do hand sinks have to drain to the grease trap?

    No. Under Austin Water's criteria, hand sinks are not required to be plumbed to the grease trap. A hand sink connected directly counts as zero fixture units. One that drains through a floor sink to the interceptor still counts.

    Can I have a garbage disposal in a commercial kitchen in Austin?

    No. Austin Water prohibits garbage disposals and grinders in commercial kitchens, because ground food solids fill the interceptor and pass grease downstream.

    Why does a dishwasher mean a 500-gallon interceptor?

    Dishwashers discharge hot water and detergent that keep grease emulsified. The larger interceptor gives it the full 12 minutes of retention (7 in the first compartment and 5 in the second) to cool and separate before it reaches the sewer.

    Is the calculator result my approved size?

    No. It's an estimate using Austin Water's published method. The approved size comes from plan review and the Industrial Waste approval letter. Get that letter before you buy the interceptor.

    Sources